Instruction Manual
3
Pin 2 - Interleave Noise Protection
OFF: If Pin 2 is in the OFF position, the 110VDSLEXT / GB / EU will operate in Interleave
mode, with communication protection for up to 250ms of impulse noise with latency
less than 6 ms
ON: If Pin 2 is in the ON position, the 110VDSLEXT / GB / EU will operate in Fast mode,
with direct data transmissions having less than 1ms of latency.
Pin 3 - Band Plan
OFF: If Pin 3 is in the OFF position, the 110VDSLEXT / GB / EU will operate in Symmetric
mode, with both downstream and upstream transmissions operating on the G.997
band plan.
ON: If Pin 3 is in the ON position, the 110VDSLEXT / GB / EU will operate in Asymmetric
mode, with asymmetric short range transmissions operating at the highest available
line rate.