HP BladeSystem c3000 Enclosure
technology brief, 2nd edition
Abstract.............................................................................................................................................. 3
Overview of HP BladeSystem c3000 Enclosure ....................................................................................... 3
Managing the c3000 enclosure ............................................................................................................ 5
Onboard Administrator..................................................................................................................... 5
Detecting component insertion and removal..................................................................................... 5
Identifying components ................................................................................................................. 6
Managing power and cooling ....................................................................................................... 6
Controlling components................................................................................................................. 6
User interfaces for Onboard Administrator ...................................................................................... 8
Security....................................................................................................................................... 8
Role-based user accounts............................................................................................................... 8
Integrated Lights-Out 2 for c-Class server blades .................................................................................. 9
Insight Display ................................................................................................................................. 9
Onboard Administrator cabling ....................................................................................................... 10
Enclosure link cabling..................................................................................................................... 11
Enclosure-based DVD ROM................................................................................................................. 12
Enclosure KVM Module ...................................................................................................................... 12
Interconnect options and infrastructure.................................................................................................. 13
Interconnect modules ...................................................................................................................... 15
Server blades ................................................................................................................................16
Storage and other option blades...................................................................................................... 16
Mezzanine cards ........................................................................................................................... 17
Virtual Connect.............................................................................................................................. 18
Fabric connectivity and port mapping............................................................................................... 18
c3000 bay-to- bay crosslinks ........................................................................................................... 21
Device bay crosslinks.................................................................................................................. 21
Interconnect bay crosslinks .......................................................................................................... 22
HP Thermal Logic technologies ............................................................................................................ 22
Active Cool fans ............................................................................................................................ 23
HP PARSEC architecture.................................................................................................................. 24
Parallel...................................................................................................................................... 24
Redundant and scalable.............................................................................................................. 25
Thermal Logic for the server blade.................................................................................................... 26
Power supplies and enclosure power subsystem................................................................................. 27
Pooled power configuration and power redundancy options ........................................................... 29
Dynamic Power Saver mode ........................................................................................................ 30
HP Power Regulator for ProLiant ................................................................................................... 31
Power Capping for each server blade........................................................................................... 31
Power meter .............................................................................................................................. 31
Seitenansicht 0
1 2 3 4 5 6 ... 37 38

Inhaltsverzeichnis

Seite 1

HP BladeSystem c3000 Enclosure technology brief, 2nd edition Abstract...

Seite 2

configured, the Insight Display verifies that there are no installation or configuration errors. The Installation Wizard turns off the enclosure UID

Seite 3 - Abstract

Figure 6. HP BladeSystem c3000 Onboard Administrator link module Enclosure link cabling The Onboard Administrator link module contains two enclos

Seite 4

Enclosure-based DVD ROM The HP BladeSystem c3000 Enclosure has an optional CD/DVD ROM drive that installs in the front of the enclosure. The Insight

Seite 5 - Managing the c3000 enclosure

Figure 7. Optional c3000 KVM Module – KVM menu screen Interconnect options and infrastructure A key component of the c3000 enclosure is the I/O i

Seite 6

Figure 8. Diagram of the HP BladeSystem c3000 signal midplane By taking advantage of the similar four-wire differential transmit and receive mecha

Seite 7 - BladeSystem c3000 Enclosure

Figure 9. Logically overlaying physical lanes (right) onto sets of four traces (left) Each device bay connector has a 100-pin signal connector wit

Seite 8

Each interconnect module also provides external connectors that vary based on the particular design. In the c3000 enclosure, pairs of single-wide int

Seite 9 - Insight Display

a Smart Array controller to enable hardware-based RAID configurations. A mezzanine card is not required to connect a half-height server blade to a di

Seite 10

4x DDR single-port mezzanine card will work equally well in Mezzanine 1, Mezzanine 2, or Mezzanine 3 connectors. Both types of mezzanine cards use a

Seite 11 - Enclosure link cabling

Figure 10. HP BladeSystem c3000 interconnect bay numbering For interconnect bay mapping purposes, it does not matter in which device bay a server

Seite 12 - Enclosure KVM Module

HP BladeSystem Power Sizer ... 31 Summary ...

Seite 13

interconnects. It connects embedded Ethernet NICs to the internal facing ports on the Ethernet interconnect. Depending on the configuration requireme

Seite 14

signal midplane are allocated to the adjacent device bay. A four-port PCIe x8 mezzanine card installed in connector 2 PCIe x8 can send x2 signals to

Seite 15 - Interconnect modules

Figure 13. HP BladeSystem c3000 device bay crosslinks as indicated by the arrows Interconnect bay crosslinks Interconnect bay crosslinks are wired

Seite 16 - Server blades

HP Thermal Logic technologies include many elements and capabilities: • Active Cool fans • Parallel Redundant Scalable Enclosure Cooling (PARSEC) d

Seite 17 - Mezzanine cards

Figure 15. Ducted fan cross-section and ducted fan blade compared to traditional server fan HP PARSEC architecture The c3000 enclosure uses PARSEC

Seite 18 - Virtual Connect

Figure 16. HP BladeSystem c3000 self-sealing enclosure Redundant and scalable BladeSystem c3000 enclosures ship with four installed fans that pro

Seite 19

Figure 17. The c3000 enclosure fan bay and device bay population guidelines Thermal Logic for the server blade Precise ducting on HP server blade

Seite 20

Figure 18. Processor heat sink using fully ducted design (left) and a traditional heat sink in a 1U rack-mount server (right) Instant Thermal Moni

Seite 21

Figure 19. HP BladeSystem c3000 Enclosure supports up to six power supplies High efficiency HP c3000 power supplies provide greater than 90 percen

Seite 22

Figure 20. Remote site solution includes a c3000 enclosure with UPS and local KVM in a small 14U rack NOTE The rack-mountable HP R5500 UPS (5000VA

Seite 23 - Active Cool fans

Abstract The HP BladeSystem c3000 Enclosure is the next generation in an evolution of the entire rack-mounted infrastructure. The c3000 enclosure is

Seite 24 - HP PARSEC architecture

Figure 21. Redundant HP BladeSystem c3000 power supplies connected to an HP R5500 UPS Connecting to PDUs with AC redundancy to each rack In an N+N

Seite 25

NOTE In redundant environments using Dynamic Power Saver mode, a minimum of two power supplies are always active. The maximum load for any power supp

Seite 26

type, application utilization, and ambient temperature. The BladeSystem Power Sizer is available at the following URL: http://www.hp.com/go/bladesyst

Seite 27

Appendix. Fan, power supply, and device bay population guidelines Figure A-1. Fan population guidelines for HP BladeSystem c3000 Enclosure. For corr

Seite 28

Figure A-2. Power supply population guidelines for HP BladeSystem c3000 Enclosure Table A-1. Power supply placement for HP BladeSystem c3000 Encl

Seite 29 - (N+1) power mode

Figure A-3. Full-height server blade device bay numbering for HP BladeSystem c3000 Enclosure. Full--height servers should be populated from bottom t

Seite 30

CAUTION To prevent improper cooling or thermal damage, do not operate the server blade or the enclosure unless all device bays are populated with eit

Seite 31

37 CAUTION If a full-height server blade is installed in device bay 1/5 and half-height server blades are installed in device bays 2 or 6, removing t

Seite 32 - Summary

For more information For additional information, refer to the resources listed below. Resource description Web address General HP BladeSystem infor

Seite 33

Figure 2. HP BladeSystem c3000 Enclosure – rear view The HP BladeSystem c3000 Enclosure has redundant signal paths between servers and interconne

Seite 34

Table 1. Components supported by HP BladeSystem c-Class enclosures Enclosure c3000 c7000 Model Rack (6U) or Tower Rack (10U) Blade orientation H

Seite 35 - IMPORTANT

the component. If a component is removed from a bay, the Onboard Administrator deletes the information about that component. Identifying components T

Seite 36

Figure 3. Management communications between Onboard Administrator and other components in an HP BladeSystem c3000 Enclosure c3000 internal managem

Seite 37

service port that allows users to temporarily connect a laptop PC to any of the linked enclosure Onboard Administrators for local diagnostics and deb

Seite 38 - Call to action

user credentials. Two-factor authentication allows even tighter security for the user management session to the Onboard Administrator. Rather than r